STIR FAQ
Frequently asked questions about how to use STIR.
How to display images generated by STIR?
STIR comes witha very basic utility called manip_image that displays image slices, but it is really only useful for a quick check (or to see if STIR did read your image as expected). Your best option is to use an external display program.
By default, STIR uses a version of the Interfile format, although only a subset of keywords is implemented. (See the STIR web-site for more links on Interfile).
Amide and xmedcon read STIR .hv files without trouble as long as the data-offset is zero (e.g. files which are written by STIR). Other packages might ignore the scale factor (but STIR by default writes as floats with scale factor 1). And other packages might insist on using the official Interfile 3.3 standard. The .ahv files written by STIR are closer to that, but they have a tweak to let Analyze (from the Mayo) read them correctly (as Analyze misinterprets the z-spacing). Open one of the .ahv files in your text editor and read the comments.
STIR currently uses a home-grown way to specify the image origin. No other program supports this convention as far as we know (as Interfile currently does not have relevant keywords). STIR currently completely ignores patient orientation etc. So if you have an image of the same object written by a different program, and the display program tries to interpret coordinate systems, it's unlikely the 2 objects will be displayed in the same location.
How does the STIR coordinate system work (e.g. for generate_image)
Details on orientation etc are given in the STIR Developer's guide. Here we attempt to give some more info on the origin and how this works for images. This is somewhat complicated because the relation with the scanner needs to be considered.
STIR coordinates are currently related to the scanner, i.e. not to the patient (as in DICOM). A peculiarity is that STIR coordinates are ordered (z,y,x) (with z along the scanner axis, y vertical and x horizontal).
Images
Currently, STIR does not support rotated coordinate systems. Therefore, we only need to give the location of the origin. Inside STIR, this origin can be shifted around using the offset. However, we will first assume that you did not do this ("zero offset").
- For an image with zero offset, the origin is assumed to coincide with the centre of the first plane.
Let's say you want to use generate_image to create a cylinder in the centre of the (3D) image (and we use zero offsets for the image and an odd-number of pixels in x,y, see below). Then we need to compute the STIR coordinates of the centre. Given that (0,0,0) is at center of the first plane, the center of the last plane is at ((num_planes-1)*z_voxel_size,0,0). And therefore, the middle of the image is at ((num_planes-1)*z_voxel_size/2,0,0).
There's a small complication. When you have an odd number of voxels in x (or y), the 0 coordinate is indeed in the centre of the image. But if you have an even number, it's actually half a pixel off. This convention is probably different from other programs, therefore
- We recommend to use odd number of voxels in all 3 directions.
For an existing image, you can use the list_image_info utility to get some information on geometry.
When developing code in STIR, you want to use the functions
DiscretisedDensity::get_physical_coordinates_for_indices()
etc to find out what the location
of the centre of a particular voxel is.
Projection data
This coordinate system is currently never exposed to the user, but only the developers. Functions like
ProjDataInfo::get_m()
use a coordinate system where (0,0,0) is the centre of the (gantry of the) scanner.
There's unfortunately also a set of obsolete function (which will be removed) that use a coordinate system
where (0,0,0) in the centre of the first ring of the scanner (e.g. find_cartesian_coordinates_of_detection
).
For all "segments" (see the STIR glossary), the data is assumed to be centred to the scanner (taking their average ring different into account).
Combining images and projection data
When you are forward projecting an image or reconstructing projection, you need to know what the relation between the 2 conventions is. Unfortunately, STIR does not support different "bed positions" yet. For backwards compatibility, the following convention is used.
- For images with zero offset, the middle of the scanner is assumed to coincide with the middle plane of the image.
So, for the generate_image example above, the cylinder would be located in the centre of the scanner.
- WARNING: the combination of these conventions means that if you change the number of planes in the image, you also have to change the "origin" of the shape such that it would forward project into the same projection data.
You can see this clearly from the formulas used in the generate_image example above.
However, this convention is confusing and therefore might be changed in the future. Together with a current limitation of the STIR projectors, this leads us to the following:
- We recommend that you use images which have 2*(num_rings-1) planes with z-voxel-size equal to ring_spacing/2.
Using images with non-zero offset
It is possible to create images where a different origin is used. How you do this depends on the file format, but for Interfile, this can be done by changing the first pixel offset (mm) keywords. This is not recommended of course.
The only STIR utility that creates images with non-zero offset is zoom_image. It is designed such that if you specify zero offsets and all image sizes are odd, the object will remain in the same physical location compared to the scanner. Its usage is
zoom_image <output filename> <input filename> \ sizexy [zoomxy [offset_in_mm_x [offset_in_mm_y \ [sizez [zoomz [offset_in_mm_z]]]]]]]
If you need to zoom an image (e.g. for estimate_scatter), it is therefore highly recommended to use zoom_image (as opposed to trying to figure out yourself where the objects will go).
As a developer, you can create images with non-zero offset using the VoxelsOnCartesianGrid
constructor with non-zero origin. This is not recommended however for future compatibility. The stir::zoom_image
function should be safe.
ERROR: DataSymmetriesForBins_PET_CartesianGrid can currently only support z-grid spacing equal to the ring of the scanner divided by an integer. Sorry
You can see this error when using forward projection of an image (e.g. when computing attenuation correction factors), or backprojection to an image. It happens because the projectors try to save memory (and time) by using a symmetry in the axial direction. To avoid this error, you have to use a z-spacing for the image which is half the ring-spacing of the scanner. (Although the symmetries could be used in other cases as well, there seem to be some problems with the projectors in such cases in the current version of STIR).
Unless you're building STIR on some exotic or very recent system, the building process should be straightforward (after reading the STIR_UsersGuide!).
Prerequisites
Before building, on Ubuntu and debian, you should do the following
apt-get install gcc g++ make libncurses-dev libX11-dev libboost-dev tcsh
(prefix with sudo for Ubuntu). The User's guide contains details for other systems.
What's the difference between "make all" and "make install"?
"make all" (or indeed "make") will only compile. "make install" will copy executables and a few scripts to ${INSTALL_PREFIX}/bin.
The "install" target "depends" on "all", i.e. "make" will implicitly do update "all" before doing "install". That's a complicated way to say you need only "install".
By the way, with current STIR Makefiles, "make test" will first check if the library is compiled and up-to-date, and if not, build it. In contrast, for the Makefiles generated by 'CMake', "make test" will run the compiled test executables without checking if they are up-to-date.
Common compilation errors
Problems with missing include files
For instance
gcc -O3 -DNDEBUG -ffast-math -I/opt/STIR/include -DHAVE_SYSTEM_GETOPT -DSTIR_SIMPLE_BITMAPS -DSC_XWINDOWS -o opt/display/gen.o -MMD -MP -c display/gen.c ; In file included from display/gen.c:24:0: display/gen.h:114:48: fatal error: curses.h: No such file or directory compilation terminated.
This message is telling you that you need the curses.h file (it is used in STIR when selecting GRAPHICS=X). See #Prerequisites (and the User's Guide) for installing extra packages.
Problems with boost
You do have boost, but are getting a compilation error as follows
./include/boost/config/compiler/gcc.hpp:92:7: warning: #warning "Unknown compiler version - please run the configure tests and report the results"
You need to upgrade your boost version. Your compiler version is more recent than the boost version that you have.
Recent compilers
STIR 2.1 (and earlier) cannot be compiled with very recent compilers such as gcc 4.6.x or CLang++. This problem is fixed in STIR 2.2. See the stir-users mailing list for more info. Example error:
/opt/STIR/include/stir/numerics/BSplines_weights.inl:344:50: error: uninitialized const ‘stir::BSpline::near_n_BSpline_function’ [-fpermissive] /opt/stir_2.1/include/stir/numerics/BSplines_weights.inl:78:9: note: ‘const class stir::BSpline::BSplineFunction<(stir::BSpline::BSplineType)0u, double>’ has no user-provided default constructor
Problems with linking
These errors occur after a long time in the building process as all "object files" will be compiled first, before the executables will be build by linking the object files and the libraries. Errors would say something like a missing library.
You probably miss some development libraries. See the installation guide.
Why do the tests of the recon_test_pack fail?
Most likely this due to a bug in the "incremental backprojector" which crops up depending on compiler/optimisation settings etc. An extensive discussion of this bug appeared on the STIR users lists. You might be able to see this using this link.
For example, a known system that has this problem is Ubuntu 64bit using gcc 4.5 in 64 bit mode (and -O3).
There are several ways to check:
- run recon_test_pack with the --nointbp flag to remove tests that use this projector
- display the sensitivity image that you're getting. Most likely you'll see a hot spot in the middle or some 45 degree lines
You could always compile as 32bit even on 64bit linux of course (use EXTRA_CFLAGS=-m32 EXTRA_LINKFLAGS=-m32, and don't forget to either change DEST or make clean). However, we do not recommend using the incremental backprojector for the iterative algorithms anyway as there's no corresponding forward projector.
What are good settings for the reconstruction programs?
This is unfortunately a very hard question to answer. Look for some advice on the mailing lists. Note that the STIR defaults are not optimal, and neither are the sample .par files (and most definitely not the .par files in the recon_test_pack). A few things that seems pretty clear:
Should I change the default projectors used by the reconstruction?
The current (STIR 2.2 and earlier) default for the iterative reconstructions is to use a ray tracing forward projector and an incremental interpolating backprojector. This turns out to be a bad choice as these projectors are not matched, which creates problems (even if the incremental backprojector does work on your system, see the known problems). It's probably best to use matched projectors, and the easiest way to do that is to use a "matrix". The fastest is the ray tracing matrix, but this defaults to using only 1 ray per bin in the sinogram. This is not ideal, and for instance creates discretisation artefacts in the high count situations. For the iterative algorithms, you should therefore probably use something like this in your .par file:
projector pair type:= Matrix Projector Pair Using Matrix Parameters:= Matrix type:= Ray Tracing Ray tracing matrix parameters:= number of rays in tangential direction to trace for each bin:= 10 End Ray tracing matrix parameters:= End Projector Pair Using Matrix Parameters:=
For the analytic algorithms, using a ray tracer as backprojector can create (other) discretisation artefacts. You can alleviate this by using more rays, but in 3D, the ray tracing matrix doesn't take a Jacobian into account (as you don't have for iterative reconstructions). Either stick to the default interpolating backprojector, or use its matrix equivalent. See the User's Guide.
How many subsets should I use?
If you can afford to wait: 1. Otherwise as small as possible. However, because the STIR projectors use symmetries (unless you switch them off) the number of subsets needs to divide number_of_views/x where x is 4,2 or 1 depending on which x gives you an integer number in the division (when using all symmetries). For example, if you have 210 views, x=2, so you could use 1,3,5,7 and their multiples that still divide 105.
Which regularisation method should I use?
Kris Thielemans doesn't like "early stopping". Post-filtering is straughtforward (but you need to iterate longer than you think). You can use inter-iteration filtering or penalised reconstruction, but be aware that these create non-uniform resolution/regularisation. This is well-known in the literature, and can be fixed in STIR, but the relevant code is not yet available. (Remember also that OSL can diverge in noisy cases when the regularisation is too high).
In any case, you should normally not mix different regularisation methods (unless you know what you're doing of course).
Content license